Baseline® Raises the Bar in Photoionization Detection Technology: Introducing

New and improved piD-TECH Photoionization Detector offers lower detection limits and greater consistency.

Lyons, CO - December 16, 2014 - (iNewswire)

Baseline® a MOCON® company introduces the piD-TECH® eVx, a new line of OEM Photoionization Detectors. In an effort to continue to improve our products and bring value to our customers, Baseline has developed a new version of the piD-TECH Photoionization Sensor. The new version is the piD-TECH eVx.

The eVx has improvements in both performance and price. Key improvements are; greater stability over temperature changes, minimal humidity effects, internal shielding and an internally regulated supply voltage able to accept input voltages from 3.2V to 5.5V.

The piD-TECH eVx detection capabilities and minimum detection quantity (MDQ) are denoted by color.

Green: Range 10,000 ppm - MDQ 1,000 ppb

Purple: Range 2,000 ppm - MDQ 500 ppb

Red: Range 200ppm - MDQ 50 ppb

Yellow: Range 20 ppm - MDQ 5 ppb

Blue: Range of 2 ppm - MDQ 0.5 ppb

Baseline’s line of OEM detectors is designed with a 4P platform for design and installation ease in portable or stationary gas detection equipment.

Some common applications for the piD-TECH eVx sensor include indoor air quality, industrial hygiene, safety monitoring, confined space entry, soil contamination, remediation, hazmat sites, spills and low-concentration leak detection.

For more product specific information, please contact info@baselineindustries.com or visit our website at www.baseline-mocon.com.

About Baseline, a MOCON company: With over four decades in the industry, Baseline sets the standard in the development and manufacture of gas chromatographs, hydrocarbon analyzers, OEM sensors and portable detection instruments including the recent addition of state of the art instrumentation for measuring environmental water quality.

This press release contains forward-looking statements that involve a number of risks and uncertainties. Important factors that could cause actual results to differ materially from those indicated by such forward-looking statements include but are not limited to: uncertainties relating to competition and technological change, setbacks in product development program, slower-than-anticipated customer acceptance of new products, dependence on certain key industries, risk associated with the Company’s acquisition strategy and international operations and other factors set forth in the Company’s filing with the Securities and Exchange Commission.

# # #

Contact Info:
Baseline
Po Box 649 / 19661 Highway 36
Lyons
CO 80540
United States

Press Release Service by I-Newswire.com

Original Source: Baseline® Raises the Bar in Photoionization Detection Technology: Introducing
Data & News supplied by www.cloudquote.io
Stock quotes supplied by Barchart
Quotes delayed at least 20 minutes.
By accessing this page, you agree to the following
Privacy Policy and Terms and Conditions.